21
Problem
LED constant on
Red LED not
on during
a call for
heat. Heater
does not
operate.
Normal Operation
Is heater
connected to its
power supply?
Connect it to the
power supply.
Yes
No
Yes
Is
proper
voltage supplied
to heater power cord
and through
power cord?
Check dataplate for electrical supply
requirements. Provide proper
voltage. Check circuit breakers.
Check power cord for continuity.
Are 24 volts
supplied from
transformer?
Replace 40 VA
transformer
No
No
No
Yes
Are
24 volts supplied
to ignition
module?
Poor electrical connection
or broken wire present.
Repair or replace.
Yes
Replace ignition module.
Is
proper
voltage supplied
to 40 VA
transformer?
Check electrical
connections and
power supply to
transformer.
Repair as necessary.
No
Yes
Yes
Is
building controller
calling for heat?
Set controller to
call for heat.
No
Heater does not
cycle above
minimum heat
output.
Is building
controller
calling for
heat?
No
Is proper gas
pressure supplied
to heater?
Yes
Provide proper
pressure to heater and
check with a gauge.
No
Set the building
controller to call for
heat.
Is variable rate
solenoid on gas
control valve receiving
DC volts ?
No
Yes
Problem
Measure across terminals of modulating gas
control valve for anywhere from 1-15 volts DC.
If absent, check all wiring and building
controller settings. If wiring and settings are
good, replace the signal conditioner.
Defective variable
rate gas control
solenoid. Replace
gas control.
Yes
Is the 20 VA
transformer
recieving 115 volts
and supplying 24
volts to signal
conditioner?
No
Check electrical connections
and power supply to transformer.
If no power from transformer to
conditioner, replace the
transformer.
Yes
LED Flashing
One Time
Air proving switch
contacts are closed
before fan motor is
started. Fan motor does
not run. Heater does
not light.
Is air-
proving switch
shorted? (Perform
continuity check on air-
proving switch.)
Yes
No
Yes
Replace air-proving
switch
Is air-proving switch
arm or paddle binding
on housing? Is there
an obstruction in
heater outlet?
Repair and/or remove
obstructions. check
for damaged fan
housing. Clean or
repair as needed.