Lb-white Guardian with Smart Sense / Direct Connect - Spark Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Heizkörper Lb-white Guardian with Smart Sense / Direct Connect - Spark herunter. L.B. White Guardian with Smart Sense / Direct Connect - Spark Ignition (250K) User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 30
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
MODELS OUTPUT (Btuh) FUEL
AD250 250,000
Owner's Manual and Instructions
GUARDIAN
®
Agricultural Animal Confinement Building Heaters
with
Smart Sense
Automatic Variable Rate Heat
For Direct Connection to a Building Controller
View this manual online at www.lbwhite.com
150-29319
Congratulations!
You have purchased the finest agricultural building heater available.
Your new L.B. White heater incorporates the benefits from the most experienced
manufacturer of heating products using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products and
welcome any suggestions or comments you may have...call us, toll-free,
at 1-800-345-7200.
ATTENTION ALL USERS
This heater has been tested and evaluated by C.S.A. International in accordance
with ANSI/IAS U.S. LC2-1998 as well as the Canadian Gas Association Standard for
Gas Fired Brooders, CAN1-2.20-M85 and is listed and approved as a direct gas-fired
circulating heater for the heating of agricultural animal confinement buildings.
To utilize the Smart Sense
automatic variable rate gas control valve, the heater
must be connected to an automated building controller capable of providing a
0-10 VDC, 0-20 milliamp signal, or 4-20 milliamp signal. If you are considering
using this product for any application other than it’s intended use, please contact
your fuel gas supplier, or the L.B. White Co., Inc.
Patent Pending
Propane-Vapor
Withdrawal or
Natural Gas
SCAN THIS QR CODE
with your smartphone or
visit http://goo.gl/nksqZ to
view maintenance videos
for L.B.White heaters.*
*Requires an app like QR Droid for Android or
QR Reader for iPhone.
Seitenansicht 0
1 2 3 4 5 6 ... 29 30

Inhaltsverzeichnis

Seite 1 - Congratulations!

MODELS OUTPUT (Btuh) FUELAD250 250,000Owner's Manual and InstructionsGUARDIAN ®Agricultural Animal Confinement Building Heaters with Smart Sense™

Seite 2

12. A qualified service agency must check for properoperating gas pressure upon installation of theheater.13. Light according to instructions on heate

Seite 3

1. Assemble according to the illustration and tighten alleyebolts securely. See Fig. 3.FIG. 32. Be sure heater is securely fastened and is hangingleve

Seite 4 - General Information

11MANUAL SHUT-OFF VALVE, HOSEAND REGULATOR ASSEMBLYREGULATORNIPPLEREGULATOR VENTGAS HOSEADAPTERSEDIMENT TRAPTO CONTROLVALVE INLETGANIPPLEVALVE, MANUAL

Seite 5 - Heater Specifications

12 The Smart Sense™variable rate heater incorporates asignal conditioner board in the control box. This signalconditioner takes the control signal s

Seite 6 - Basic Operation

Follow steps 1 - 6 on initial start-up after heater installationby a qualified gas heater service person. For normal start-up, set the building contr

Seite 7 - Safety Precautions

WARNINGThis heater may be washed only on the external caseassembly provided:A. The heater is disconnected from the electricalsupply.B. All access pane

Seite 8

151. Remove the screws securing the motor mountingplate to the fan housing.2. Pull the fan and motor assembly from the housing.3. Loosen the square he

Seite 9 - Installation Instructions

16SIGNAL CONDITIONERIf replacing the signal conditioner: Handle the replacment conditioner at its edges. Don’t touch the signal conditioner compone

Seite 10 - INSTALLATION INSTRUCTIONS

TESTING THE MANUAL RESET HIGH LIMIT SWITCHWARNINGFire Hazard Do not operate the heater with the high limit switchbypassed. Operating the heater a

Seite 11 - SEDIMENT TRAP ASSEMBLY

The following explains a typical procedure to be followed inchecking gas pressures. Consult the dataplate on the heater or page 4 in thismanual for

Seite 13

19READ THIS ENTIRE SECTION BEFOREBEGINNING TO TROUBLESHOOT PROBLEMS.The troubleshooting flow charts on the following pagesprovide systematic procedure

Seite 14 - Shut-Down Instructions

OPERATION SEQUENCE:— A call for heat occurs from the building controller.— 115 VAC is sent to:-- 40 VA transformer and to ignition control-- 20 VA tr

Seite 15 - Maintenance Instructions

21ProblemLED constant onRed LED noton during a call forheat. Heaterdoes notoperate.Normal OperationIs heaterconnected to itspower supply?Connect it t

Seite 16 - CLEARANCE

22Two TimesAir provingswitch do notclose during acall for heat. Are air provingswitch contactsstuck open?(Perform continuitycheck.)Does fan motor star

Seite 17 - IGNITER AND FLAME SENSOR

23Three TimesIgnition failure. The module hasgone into safetylockout.Is LP tankfull and properly sized and are all gas supply valves to heater open?F

Seite 18 - IGNITION CONTROL

24If ignition control module does not reset, then replace the control. (Internal fault.)If ignition control module resets, then have qualified elect

Seite 19 - Gas Pressure Checks

25Electrical Connection and Ladder Diagram++1 2 6 7 5 3

Seite 20 - Troubleshooting Instructions

26Heater Component FunctionAir Proving Switch Safety device used to insure that the proper air flow is beingachieved before the gas valve is opened.

Seite 21

27Parts IdentificationPARTS SCHEMATIC

Seite 22

28Parts IdentificationPARTS LISTItem Description Part Number1 Valve, manual shut off with nipple 03399*2 Regulator, Second stage, vent over outlet

Seite 23

WARNINGFire and Explosion Hazard Not for home or recreational vehicle use. Installation of this heater in a home orrecreational vehicle may result i

Seite 24

Contact your local L.B. White dealer for replacement partsand service or call the L.B. White Co., Inc. at 1-800-345-7200for assistance. Be sure that

Seite 25

This Owner's Manual includes all options and accessoriescommonly used on this heater. However, depending on theconfiguration purchased, some opt

Seite 26 - 1 2 6 7 5 3

4SPECIFICATIONSMaximum Input (BTUH) 250,000Minimum Input (BTUH) 65,0001,050 11.0 9.510.0 7.50.511.58 lbs. 250 cu.ft3.01 lbs. 65 cu.ft1/3 H.P.1100 RPM1

Seite 27 - Heater Component Function

5Basic OperationThis heater uses Smart Sense™ technology for variablerate heat control. L.B.White has worked with agriculturalbuilding control manufac

Seite 28 - Parts Identification

6Propane gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.If a gas leak occurs, you should be able to sme

Seite 29

1. Do not attempt to install, repair, or service this heateror the gas supply line unless you have continuingexpert training and knowledge of gas heat

Seite 30 - Replacement Parts and Service

1. Read all safety precautions and follow L. B. Whiterecommendations when installing this heater. Ifduring the installation or relocating of heater,

Kommentare zu diesen Handbüchern